{"id":2368,"date":"2022-09-23T12:34:02","date_gmt":"2022-09-23T12:34:02","guid":{"rendered":"https:\/\/lumoscontrols.com\/resources\/?p=2368"},"modified":"2023-01-02T16:06:41","modified_gmt":"2023-01-02T16:06:41","slug":"motion-sensors-how-and-why-should-commercial-space-install-it","status":"publish","type":"post","link":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/","title":{"rendered":"Motion sensors: How and why should commercial space install it?\u00a0"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-1024x576.jpg\" alt=\"Motion sensors in commercial space\" class=\"wp-image-2369\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-1024x576.jpg 1024w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-300x169.jpg 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-768x432.jpg 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-1536x864.jpg 1536w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-338x190.jpg 338w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-24x14.jpg 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-36x20.jpg 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571-112x63.jpg 112w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>From some years now, business owners are always on the lookout to save money and installing of motion sensors is one such way to achieve the same. Motion sensors can automatically turn lights ON or OFF based on whether there are people in the room. By installing sensors, you avoid the risk and expense of having lights ON when you don\u2019t need them. The most frequently used motion sensors in IoT applications are <a href=\"https:\/\/wisilica.com\/company\/lighting-with-occupancy-and-vacancy-sensors-2\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Passive Infrared (PIR)<\/mark><\/a>&nbsp; and Microwave sensors. Check our <a href=\"https:\/\/lumoscontrols.com\/resources\/microwave-vs-pir-motion-sensors\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">previous blog<\/mark><\/a> on Microwave Vs PIR to learn more.&nbsp;&nbsp;<\/p>\n\n\n\n<p>Motion sensors are required in any well-designed commercial space and this article will explain why they are a must in increasing energy savings and building efficiency. We will also explain their application in different commercial verticals along with.&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<h1><strong>Meeting Big three energy codes and standards&nbsp;<\/strong><\/h1>\n\n\n\n<p>Energy Standard for Buildings, except for low-rise residential buildings, require lights to automatically turn off or dim in spaces like conference rooms, classrooms, corridors, lecture halls, enclosed offices, etc., within 30 minutes of the space being unoccupied. Occupancy\/ vacancy sensors help achieve this requirement.<\/p>\n\n\n\n<p>Want to learn more about the big three energy codes and standards, check out our <a href=\"https:\/\/lumoscontrols.com\/resources\/is-your-lighting-system-up-to-code\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">previous blog<\/mark><\/a>.<\/p>\n\n\n\n<h2><strong>ASHRAE \u20132019 (9.4.1.1)&nbsp;<\/strong><\/h2>\n\n\n\n<ul><li>Automatically shut off lights within 20 minutes of vacancy &nbsp;<\/li><li>Shutoff or automatically reduce lighting by at least 50 % within 20 minutes of vacancy&nbsp;&nbsp;<\/li><li>None of the lighting in the space shall be automatically turned ON &nbsp;<\/li><\/ul>\n\n\n\n<h2><strong>Title 24&nbsp;<\/strong><\/h2>\n\n\n\n<ul><li>Automatic control turns lighting ON upon occupancy or OFF after a vacancy of 20 minutes or less. When manual ON is used, provide a vacancy sensor which does not allow for automatic ON.&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned ON to maximum lighting power&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned ON to 50% to 70% of maximum lighting power&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned OFF&nbsp;<\/li><\/ul>\n\n\n\n<h2><strong>IECC&nbsp;&nbsp;<\/strong><\/h2>\n\n\n\n<ul><li>Automatic control turns lighting ON upon occupancy or OFF after a vacancy of 20 minutes or less.&nbsp;&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned ON to maximum lighting power.&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned ON to 50% or less of maximum lighting power.&nbsp;<\/li><li>Lighting is turned ON manually by an occupant.&nbsp;<\/li><li>When initiated by a timeclock or occupancy sensor, lighting is automatically turned OFF.&nbsp;<\/li><li>In vacant corridors, warehouse aisles, open office zones, and parking garage zones, lighting is automatically reduced by at least 50% of maximum lighting power (80% for open office, 30% for parking garages). Automatic full OFF also complies.&nbsp;<\/li><\/ul>\n\n\n\n<h1><strong>Sensor placement \u2013 Use cases&nbsp;<\/strong><\/h1>\n\n\n\n<p>Here, we will present examples of sensor installation in different commercial spaces including helpful hints and lighting control strategies to keep in mind.&nbsp;&nbsp;<\/p>\n\n\n\n<h2><strong>Office space&nbsp;<\/strong><\/h2>\n\n\n\n<p>In open-plan offices, there will be long rows of desks, circulation areas, lounges with couches, or open kitchen areas with plenty of seating. As open offices have a lot of people moving around, it is not necessary to have occupancy sensor coverage on every square inch of space.&nbsp;<\/p>\n\n\n\n<p><strong>Useful hints:&nbsp;<\/strong><\/p>\n\n\n\n<ul><li>Main sure to cover the walkways&nbsp;<\/li><li>Use ceiling-mounted sensors (you may also want to use wall mounted sensors if the cube walls are short)&nbsp;<\/li><li>Mounting sensors close to air vents is not recommended, as the vibration and airflow can reduce the sensor performance.&nbsp;<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"877\" height=\"332\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572.png\" alt=\"Open Office space\" class=\"wp-image-2370\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572.png 877w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-300x114.png 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-768x291.png 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-502x190.png 502w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-24x9.png 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-36x14.png 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-572-112x42.png 112w\" sizes=\"(max-width: 877px) 100vw, 877px\" \/><\/figure>\n\n\n\n<p>Enclosed\/ private office space might have only a desk and you\u2019ll have more options for sensor placement. A wall-mount or ceiling-mount occupancy sensor is your best choice. An in-wall occupancy sensor is considered if the view from the light switch to the rest of the room is not obstructed.&nbsp;<\/p>\n\n\n\n<p><strong>Useful hints:<\/strong>&nbsp;<\/p>\n\n\n\n<ul><li>Desk should be within the coverage area of the sensor&nbsp;<\/li><li>Make sure the door is in the visible area of sensor&nbsp;<\/li><li>Avoid placing sensors close to air vents, as the vibration and air flow can reduce the effectiveness of the sensor&nbsp;<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"543\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-1024x543.png\" alt=\"Enclosed\/ private office space\" class=\"wp-image-2371\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-1024x543.png 1024w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-300x159.png 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-768x407.png 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-359x190.png 359w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-24x13.png 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-36x19.png 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573-112x59.png 112w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-573.png 1185w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2><strong>Classrooms&nbsp;<\/strong><\/h2>\n\n\n\n<p>Occupancy sensors are specifically required in the majority of classrooms. When the occupant enters, lights must be turned ON manually or automatically to &lt;50% of lighting power. Lights must be turned OFF automatically within 30 minutes after occupants leave the space. Classrooms will be inactive during nighttime, weekends or holidays and occupancy\/vacancy sensing can ensure lighting is not left ON when space is unoccupied.&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p><strong>Useful hints:<\/strong>&nbsp;<\/p>\n\n\n\n<ul><li>Avoid ceiling-mounted occupancy sensors in classrooms, as it may obstruct sensor&#8217;s views&nbsp;<\/li><li>Make sure sensor cover the teacher\u2019s desk, and any other areas where people might sit for long periods of time.&nbsp;<\/li><li>Mounting sensors close to air vents is not recommended, as the vibration and airflow can reduce the sensor performance.&nbsp;<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"503\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-1024x503.png\" alt=\"Classrooms\u00a0\" class=\"wp-image-2372\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-1024x503.png 1024w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-300x147.png 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-768x377.png 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-387x190.png 387w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-24x12.png 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-36x18.png 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574-112x55.png 112w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-574.png 1106w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2><strong>Corridors&nbsp;<\/strong><\/h2>\n\n\n\n<p>Corridors have an uncertain occupancy pattern and do not require continuous lighting. However, when someone passes through space, they should feel safe and secure. You\u2019ll need to consider the shape and length of the corridor and the position of entrances and doorways when designing the occupancy solution for a corridor.&nbsp;<\/p>\n\n\n\n<p><strong>Useful hints:<\/strong>&nbsp;<\/p>\n\n\n\n<ul><li>All possible access points to the corridor need to be covered by the sensor&nbsp;<\/li><li>Use a longer timeout (15 or 30 minutes)&nbsp;<\/li><li>Do not mount sensors close to air vents, as the vibration and air flow can reduce the performance of the sensor&nbsp;<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"677\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-1024x677.jpg\" alt=\"Corridors \" class=\"wp-image-2373\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-1024x677.jpg 1024w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-300x198.jpg 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-768x508.jpg 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-287x190.jpg 287w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-24x16.jpg 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-36x24.jpg 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575-112x74.jpg 112w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-575.jpg 1071w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2><strong>Lecture halls&nbsp;<\/strong><\/h2>\n\n\n\n<p>While designing occupancy sensor layout for lecture halls, you may want to consider multiple entrances, varying ceiling heights, projectors and more.&nbsp;&nbsp;<\/p>\n\n\n\n<p><strong>Useful hints:<\/strong>&nbsp;<\/p>\n\n\n\n<ul><li>Occupancy sensors don&#8217;t have to be installed in every inch of the room; only the focus areas need to be covered.&nbsp;<\/li><li>Avoid installing sensors where they might be covered by a projection screen.&nbsp;<\/li><li>Do not mount sensors close to air vents, as the vibration and air flow can reduce the performance of the sensor&nbsp;<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"817\" height=\"590\" src=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576.png\" alt=\"Lecture halls\u00a0\" class=\"wp-image-2374\" srcset=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576.png 817w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-300x217.png 300w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-768x555.png 768w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-263x190.png 263w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-24x17.png 24w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-36x26.png 36w, https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-576-112x81.png 112w\" sizes=\"(max-width: 817px) 100vw, 817px\" \/><\/figure>\n\n\n\n<h2><strong>Here is how we could apply occupancy\/Vacancy sensors lighting control strategy in different spaces&nbsp;<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Controls <\/strong><\/td><td><strong>Enclosed <br>space<\/strong><\/td><td><strong>Open plan<br>Office<\/strong><\/td><td><strong>Classrooms<\/strong><\/td><td><strong>Corridors<\/strong><\/td><td><strong>Lecture<br>hall<\/strong><\/td><\/tr><tr><td>Automate light level via <br>occupancy<\/td><td><\/td><td>Yes <\/td><td>Yes <\/td><td>Yes <\/td><td>Yes <\/td><\/tr><tr><td>Auto OFF via occupancy sensor<\/td><td>Yes <\/td><td>Yes <\/td><td>Yes <\/td><td>Yes <\/td><td>Yes <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Making the most of motion sensors<\/strong>&nbsp;<\/p>\n\n\n\n<p>If you are looking to set up a smart commercial space, motion sensors are simple and cost-effective option to start. These devices can help with everything from improving your comfort to reducing the amount of energy consumed on a monthly basis. And not to mention the additional efficiency and convenience that motion sensors provide. Following the tips and guidelines we\u2019ve laid out are the best approach to ensure that your motion sensors are worth the investment.&nbsp;<\/p>\n\n\n\n<p>To know more motion sensors, design, or installation, feel free to <a href=\"https:\/\/lumoscontrols.com\/contact.html\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">reach out<\/mark><\/a> to us <\/p>\n","protected":false},"excerpt":{"rendered":"<p>From some years now, business owners are always on the lookout to save money and installing of motion sensors is one such way to achieve the same. Motion sensors can automatically turn lights ON or OFF based on whether there are people in the room. By installing sensors, you avoid the risk and expense of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2369,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_eb_attr":"","content-type":"","inline_featured_image":false},"categories":[1],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Motion sensors: How and why should commercial space install it?\u00a0<\/title>\n<meta name=\"description\" content=\"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Motion sensors: How and why should commercial space install it?\u00a0\" \/>\n<meta property=\"og:description\" content=\"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\" \/>\n<meta property=\"og:site_name\" content=\"Lumos Controls\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-23T12:34:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-01-02T16:06:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Lumos Controls\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lumos Controls\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#organization\",\"name\":\"Lumos Controls\",\"url\":\"https:\/\/lumoscontrols.com\/resources\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#\/schema\/logo\/image\/\",\"url\":\"http:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/01\/logo.svg\",\"contentUrl\":\"http:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/01\/logo.svg\",\"width\":267,\"height\":69,\"caption\":\"Lumos Controls\"},\"image\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#website\",\"url\":\"https:\/\/lumoscontrols.com\/resources\/\",\"name\":\"Lumos Controls\",\"description\":\"Wireless Lighting Controls\",\"publisher\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lumoscontrols.com\/resources\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage\",\"url\":\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg\",\"contentUrl\":\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg\",\"width\":1600,\"height\":900},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\",\"url\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\",\"name\":\"Motion sensors: How and why should commercial space install it?\u00a0\",\"isPartOf\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage\"},\"datePublished\":\"2022-09-23T12:34:02+00:00\",\"dateModified\":\"2023-01-02T16:06:41+00:00\",\"description\":\"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.\",\"breadcrumb\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lumoscontrols.com\/resources\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/lumoscontrols.com\/resources\/category\/blogs\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Motion sensors: How and why should commercial space install it?\u00a0\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\"},\"author\":{\"name\":\"Lumos Controls\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/d11ba48f0991886c92d068b1ce7103d3\"},\"headline\":\"Motion sensors: How and why should commercial space install it?\u00a0\",\"datePublished\":\"2022-09-23T12:34:02+00:00\",\"dateModified\":\"2023-01-02T16:06:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/\"},\"wordCount\":1135,\"publisher\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#organization\"},\"image\":{\"@id\":\"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/d11ba48f0991886c92d068b1ce7103d3\",\"name\":\"Lumos Controls\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/6a32d50cac3b4b262805bac712c6099d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/6a32d50cac3b4b262805bac712c6099d?s=96&d=mm&r=g\",\"caption\":\"Lumos Controls\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Motion sensors: How and why should commercial space install it?\u00a0","description":"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/","og_locale":"en_US","og_type":"article","og_title":"Motion sensors: How and why should commercial space install it?\u00a0","og_description":"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.","og_url":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/","og_site_name":"Lumos Controls","article_published_time":"2022-09-23T12:34:02+00:00","article_modified_time":"2023-01-02T16:06:41+00:00","og_image":[{"width":1600,"height":900,"url":"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg","type":"image\/jpeg"}],"author":"Lumos Controls","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Lumos Controls","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/lumoscontrols.com\/resources\/#organization","name":"Lumos Controls","url":"https:\/\/lumoscontrols.com\/resources\/","sameAs":[],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lumoscontrols.com\/resources\/#\/schema\/logo\/image\/","url":"http:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/01\/logo.svg","contentUrl":"http:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/01\/logo.svg","width":267,"height":69,"caption":"Lumos Controls"},"image":{"@id":"https:\/\/lumoscontrols.com\/resources\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/lumoscontrols.com\/resources\/#website","url":"https:\/\/lumoscontrols.com\/resources\/","name":"Lumos Controls","description":"Wireless Lighting Controls","publisher":{"@id":"https:\/\/lumoscontrols.com\/resources\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lumoscontrols.com\/resources\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage","url":"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg","contentUrl":"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg","width":1600,"height":900},{"@type":"WebPage","@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/","url":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/","name":"Motion sensors: How and why should commercial space install it?\u00a0","isPartOf":{"@id":"https:\/\/lumoscontrols.com\/resources\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage"},"datePublished":"2022-09-23T12:34:02+00:00","dateModified":"2023-01-02T16:06:41+00:00","description":"This article will explain why motion sensor are a must in increasing energy savings and building efficiency along with its applications.","breadcrumb":{"@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lumoscontrols.com\/resources\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/lumoscontrols.com\/resources\/category\/blogs\/"},{"@type":"ListItem","position":3,"name":"Motion sensors: How and why should commercial space install it?\u00a0"}]},{"@type":"Article","@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#article","isPartOf":{"@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/"},"author":{"name":"Lumos Controls","@id":"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/d11ba48f0991886c92d068b1ce7103d3"},"headline":"Motion sensors: How and why should commercial space install it?\u00a0","datePublished":"2022-09-23T12:34:02+00:00","dateModified":"2023-01-02T16:06:41+00:00","mainEntityOfPage":{"@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/"},"wordCount":1135,"publisher":{"@id":"https:\/\/lumoscontrols.com\/resources\/#organization"},"image":{"@id":"https:\/\/lumoscontrols.com\/resources\/motion-sensors-how-and-why-should-commercial-space-install-it\/#primaryimage"},"thumbnailUrl":"https:\/\/lumoscontrols.com\/resources\/wp-content\/uploads\/2022\/09\/MicrosoftTeams-image-571.jpg","articleSection":["Blog"],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/d11ba48f0991886c92d068b1ce7103d3","name":"Lumos Controls","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lumoscontrols.com\/resources\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/6a32d50cac3b4b262805bac712c6099d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6a32d50cac3b4b262805bac712c6099d?s=96&d=mm&r=g","caption":"Lumos Controls"}}]}},"_links":{"self":[{"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/posts\/2368"}],"collection":[{"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/comments?post=2368"}],"version-history":[{"count":5,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/posts\/2368\/revisions"}],"predecessor-version":[{"id":2953,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/posts\/2368\/revisions\/2953"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/media\/2369"}],"wp:attachment":[{"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/media?parent=2368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/categories?post=2368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lumoscontrols.com\/resources\/wp-json\/wp\/v2\/tags?post=2368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}